RAID and NAS data recovery: don't rebuild yet.
When a RAID array or a NAS fails, the most common way to lose the data for good is the fix itself: a rebuild onto the wrong drive, a re-initialized volume, or drives put back in the wrong order. Stop, write down the configuration, and get the whole set to a lab. Per DriveSavers, RAID and NAS recovery is one of their specialties.
- Free shippingInbound, to their lab
- Free evaluationNo cost to find out
- No data, no chargeNothing recovered, nothing owed
- Certified secureSOC 2 Type II audited
What to do right now
- Don't rebuild, re-initialize, or create a new volume. If the controller or NAS offers to rebuild or initialize, decline. A rebuild onto a stale or failing drive can overwrite good data.
- Don't run file system repair. CHKDSK, fsck, and NAS repair functions write to the array.
- Label every drive with its slot number before removing anything, and keep the order. Include drives that were marked as failed: they may hold data the others need.
- Write down the configuration. The RAID level, the number of drives, the controller or NAS make and model, and what happened just before the failure. Photos of error messages help.
- Power down instead of retrying. Repeated mount and rebuild attempts stress drives that may already be failing.
Common RAID and NAS failures
A second drive fails during a rebuild
A rebuild reads every sector of the remaining drives. If another drive is weak, it can fail partway through and take the array offline.
Controller or NAS failure
The drives may be fine while the controller, the NAS unit, or its configuration has failed. The data is still on the drives, laid out in a pattern the lab reconstructs.
Re-initialized or deleted by mistake
A volume deleted, re-created, or initialized in error. Stop writing to it at once; the original data may still be on the drives.
RAID 0 with one failed drive
RAID 0 has no redundancy, so one failed drive takes the whole volume down. Recovery means repairing or imaging the failed drive and reassembling the stripe.
What to send
Send every drive from the array, labeled with its slot number, along with the configuration details. DriveSavers recovers multi-drive RAID and NAS systems for homes and businesses, and virtual machines stored on them. They walk you through exactly what to ship when you start the case.
Two ways to start
Go straight to DriveSavers
Array offline, volume missing, or a rebuild that failed: start a case with DriveSavers and use code DS22831 for 10% off. The evaluation is free and inbound shipping is free.
Start a caseBring it to us first
One drive failed and the array is still running degraded? Call us before you replace anything. If the data matters and there is no current backup, getting a copy off comes before a rebuild.
Call (585) 388-8780J&N referral code
10% off your DriveSavers recovery
Give DriveSavers this code when you start your case, or use our referral link, and they'll take 10% off. Mention it up front: it can't be added once a job is already underway.
RAID and NAS recovery questions
Can data be recovered from a failed RAID array?
Should I rebuild a degraded RAID array?
Can DriveSavers recover a Synology or QNAP NAS?
Do I need to send all the drives?
Can a RAID 0 array be recovered after a drive failure?
What does data recovery cost?
How do I get the 10% off?
Other recovery guides
Start from the main page: data recovery through DriveSavers, or data recovery in Rochester, NY.
Stop the rebuild, start a case.
Start a case with DriveSavers using code DS22831 for 10% off, or call us before you replace a drive in a degraded array.
J&N Computer Services is a DriveSavers referral partner and may receive a referral fee when you use our code or link. DriveSavers performs all recoveries and sets its own pricing, terms, and turnaround.